Type | A | Standard | IEC/EN-62606 IEC61009-1 |
---|---|---|---|
Rated Current (AC) | 6A, 10A, 13A, 16A, 20A, 25A, 32A, 40A | Poles | 2P(2Module) |
Rated Residual Current I∆n | 10mA, 30mA | Certification | UKCA, CE |
High Light | UKCA Combined AFDD RCBO,2P Combined AFDD RCBO,10mA afdd rcbo combined |
Arc fault detection devices BESTAFDD 2 Electronic type
Residual current operated circuit-breaker with integral overcurrent
protection as Fire protection switch,sensitive to pulsating and
alternating currents Type A
Function
Arc-fault detection devices(Fire protection switch, AFDD) are designed to protect serial and parallel fault arcs in accordance with EN62606(DIN VDE 0100-420).They are commonly referred to as fire protection switches. They must be installed in permanently installed final circuits up to 40A. for example. facilities at risk of fire or public institutions.They are also recommended for bedrooms and for final circuits with high connection loads.The devices detect high-frequency arc faults, such as those occurring as a result of cabling defects. The early recognition and switching off of the final circuit. which may occur as a result in the case of an emergency. prevent thermal effects of arc faults The risk of fire resulting from incorrect electrical installation is significantly reduced.The reason for tripping is indicated by an LED colour code on the front of the device. BESTAFDD 2 are compact combination devices with a triple function: arc fault detection, line protection and residual current trip.They protect systems in the event of a short-circuit and overload as per the requirements of VDE o1o Part 430, and protect persons,farm animals and material items in the event of earth leakage currents as per VDE 0100 Part 410.The RCBO component works dependent of the mains voltage.Residual current type A allows the detection of sinusoidal AC currents and pulsating DC residual currents. The contact position indicators and the display tripped by residual current provide a quick overview of the operating status of the device. The devices up to 40 A devices have a rated switching capacity of 6 kA.The line protection with characteristic B ensure standard protection for lighting and socket circuits. Devices in standard design are intended for monitoring circuits with a rated voltage of 230 V and a rated frequency of 50 Hz.
Features
combination device with three functions, 2P(2Module), Variable neutral-pole position, AFDD as per IEC/EN-62606, RCBO as per IEC/ EN61009, continuous self-monitoring, mains-voltage-dependent tripping of the RCCB/MCB functions. Display AFDD reason for tripping. Contact position indicators, Residual current tripping indicator, compact design for all rated currents, high short-circuit resistance, strain-relief clamps with protection against wires being lodged behind them, tri-stable snap-in slider for easy mounting and removal.
Applications
Protection of circuits in residential and purpose-built buildings as well as industrial facilities with TN-S and TN-C-S networks. Not permitted for use in systems with TN-C networks; not permitted for protecting circuits in which the power electronics equipment may cause smooth DC residual currents or residual currents with frequencies not equal to 50 Hz.
Performance | |
Series | BESTAFDD 2 |
Number of poles | 2P(2Module) |
Rated current (AC) | 6A, 10A, 13A, 16A, 20A, 25A, 32A, 40A |
Residual current type | A |
Rated residual current I∆n | 10mA, 30mA |
min. Operating voltage range of test circuit | 196V |
max. Operating voltage range of test circuit | 253V |
Tripping characteristic | B, C |
Operating frequency | 50Hz |
Rated impulse withstand voltage | 4 kV |
load circuit | |
Specification | load disconnect contact |
Rated voltage(AC) | 240 V |
Rated short-circuit current | 6KA |
Surge current strength | 0.25kA |
max. total rated switching capacity | 6kA |
Rated insulation voltage | 250V |
Current heat loss per current path | 3W |
short-circuit backup-fuse SCPD | 100A |
Back-up fuse type | gG |
Overvoltage class | III |
screw-type terminal top, bottom(load circuit) | |
Neutral conductor position | left, right |
max. Connection C1cable length | 70m (between the distribution board and the outer socket) |
Clamping area | 1 mm² .… 25 mm² |
Tightening torque | 2 Nm.…. 2.4 Nm |
General data | |
Mechanical endurance | min. 20000 switching cycles |
Electrical endurance | min.400o switching cycles |
Storage temperature | -35℃ ….60℃ |
Ambient temperature | -25°℃… 40℃ |
Housing type | distribution board housing |
Installation type | Mounting rail (35 mm) |
Housing material | thermoplastic |
Protection class | IP20(installed:IP40) |
Design requirements/Standards | EN62606, EN61009-1 |
Power limitation category | 3 |
Degree of pollution according to EN 60664 | 2 |
Certification | UKCA, CE |
Combined Arc Fault Detection Devices (AFDD) RCBO is a kind of over-current and short-circuit protection device designed to provide a high level of protection against electrical fires from arc fault. It offers protection level of IP20 when installed and IP40 when installed. With a power limitation category of 3, it can be mounted on a 35mm rail for secure installation. It features different rated residual current of 10mA, 30mA and rated current of 6A, 10A, 13A, 16A, 20A, 25A, 32A, 40A to accommodate various applications. Combined AFDD RCBO provides a safe and reliable protection solution for arc fault detection.
Product Name: Combined AFDD RCBO
Rated short-circuit current: 6KA
Rated voltage(AC): 240V
Ambient temperature: -25°℃… 40℃
Degree of pollution according to EN 60664: 2
Certificate: UKCA, CE
AFDD: Arc fault detection devices
RCBO: Residual current operated circuit-breaker with integral overcurrent protection as Fire protection switch,sensitive to pulsating and alternating currents Type A
The HAROK BESTAFDD 2 AFDD RCBO is an advanced residual current operated circuit-breaker with integral overcurrent protection as fire protection switch, sensitive to pulsating and alternating currents Type A. With a wide range of rated currents from 6A, 10A, 13A, 16A, 20A, 25A, 32A, 40A, this device is ideal for many commercial and residential applications. Its degree of pollution according to EN 60664 is 2, and its mechanical endurance is guaranteed to be at least 20000 switching cycles. Furthermore, it is designed to be installed on a mounting rail of 35 mm, and is able to withstand a wide range of temperatures from -35℃ to 60℃. As a result, the HAROK BESTAFDD 2 AFDD RCBO is the perfect choice for any application or situation that requires a reliable and efficient fire protection switch.
Parameter | Value |
---|---|
Product Name | Combined AFDD RCBO |
Rated Short-Circuit Current | 6KA |
Rated Residual Current I∆n | 10mA, 30mA |
Storage Temperature | -35℃ ….60℃ |
Degree of Pollution according to EN 60664 | 2 |
Rated Current | 6A, 10A, 13A, 16A, 20A, 25A, 32A, 40A |
Tripping Characteristic | B, C |
Power Limitation Category | 3 |
Housing Type | Distribution Board Housing |
Certificate | UKCA, CE |
Type | Residual current operated circuit-breaker with integral overcurrent protection as Fire protection switch,sensitive to pulsating and alternating currents Type A |
This Combined AFDD RCBO is a Residual current operated circuit-breaker with integral overcurrent protection as Fire protection switch,sensitive to pulsating and alternating currents Type A, it is designed and manufactured by HAROK.
Model Number: BESTAFDD 2
Place of Origin: CHINA
Certificate: UKCA, CE
Rated residual current I∆n: 10mA, 30mA
Rated Current: 6A, 10A, 13A, 16A, 20A, 25A, 32A, 40A
Housing material: Thermoplastic
The Combined AFDD RCBO will be packaged and shipped in a cardboard box, with the following dimensions:
Length: 25 cm
Width: 20 cm
Height: 15 cm
The box will be secured with bubble wrap and packing tape to ensure that the product reaches its destination safely.